RM Bridge Advanced Wizard Help

Temperature Page EC

The temperature is calculated according to EC 1991-1-5, 6.

Uniform temperature

SettingDescription
Uniform Consider uniform temperature load (Yes/No).
Initial temperature The default value of the initial temperature is considered by T0=10°C (see EC, Appendix A, A.1 (3)).
Te,min, Te,max Values of the minimum (Te,min) and maximum (Te,max) constant temperature part in relation to the minimum (Tmin) and maximum (Tmax) outside air temperature  with respect to the selected structure type (steel, composite, concrete) (see EC 6.1.3.1, Figure 6.1).

The values for the maximum negative (ΔTN,neg) and maximum positive (ΔTN,pos) variation of the constant temperature part are then calculated in relation to the initial temperature T0 internally as (see EC 6.1.3.3):

ΔTN,neg = Te,min – T0

ΔTN,pos = Te,max – T0

Linear temperature gradient

SettingDescription
Gradient Consider temperature gradient (Yes/No).
Delta T - positive, Delta T - negative Positive (ΔTM,pos) and negative (ΔTM,neg) linear temperature gradient with respect to the selected structure type (steel, composite, concrete) (see EC 6.1.4.1, Table 6.1).
Note: Correction factors for thickness of surfaces not included (see EC 6.1.4.1, Table 6.2).